Llamada gratuita: 800.554.1036

En las noticias

Meet the PF NeoR Double-Stage Gas Regulator for Residential Service

Introducing the PF NeoR Double-Stage Residential Gas Regulator

PF NeoR natrual gas regulator

A residential gas regulator has to hold delivery pressure steady as inlet pressure changes. How it responds to a failure also matters to utilities, because that response can affect whether customers lose service and how much natural gas is vented.

Pietro Fiorentini developed the NeoR™ residential gas regulator for low-pressure natural gas distribution. The design combines a balanced first stage with two integrated, limited-capacity relief valves. Pietro Fiorentini’s technical white paper explains how the regulator controls delivery pressure and how each stage responds to a failure.

How two-stage regulation stabilizes outlet pressure

The NeoR reduces gas pressure in two steps. The balanced first stage regulates varying inlet pressures. The second stage reduces pressure to the desired delivery pressure, which the white paper describes as typically 7 inches of water column.

Pietro Fiorentini identifies improved outlet pressure accuracy and stable performance across varying inlet pressures as benefits of the two-stage design. The NeoR also uses a common orifice across multiple inlet pressure and flow conditions, reducing the need for multiple regulator configurations.

How the NeoR limits methane venting during abnormal operation

When a slam-shut device trips, it stops gas flow and interrupts service. A conventional relief regulator can maintain gas flow while venting gas. The NeoR uses a limited-capacity token relief valve at each stage to limit how much gas is released under the failure conditions described in the white paper.

Pietro Fiorentini reports maximum vent rates of 2.5 standard cubic feet per hour (SCFH) for the first-stage relief valve and 14 SCFH for the second-stage relief valve. Actual venting depends on operating conditions and regulator setpoints.

In the catastrophic first-stage failure scenario described in the white paper, Pietro Fiorentini reports that the NeoR limits delivery pressure to approximately 1.5 psig while continuing to supply gas. Limited venting provides an indication of the abnormal condition.

Download the NeoR technical white paper

Pietro Fiorentini’s Delivering Residential Gas Pressure Regulation with Reduced Methane Emissions and Enhanced Safety includes diagrams of normal operation and first- and second-stage failure scenarios, along with a comparison of residential overpressure protection approaches.

Download the NeoR technical white paper

For product specifications or help evaluating a residential service application, explore the PF NeoR product page or contact ECCO.

 

Desplazarse hacia arriba