{"id":823,"date":"2020-04-30T16:48:35","date_gmt":"2020-04-30T16:48:35","guid":{"rendered":"https:\/\/econtrols.stagemysite.com\/product\/eagle-xartu1-volume-corrector\/"},"modified":"2020-04-30T21:54:04","modified_gmt":"2020-04-30T21:54:04","slug":"eagle-xartu1-volume-corrector","status":"publish","type":"product","link":"https:\/\/equipmentcontrols.com\/es\/producto\/eagle-xartu1-volume-corrector\/","title":{"rendered":"Corrector de volumen EAGLE XARTU1"},"content":{"rendered":"<p><strong>XARTU\/1\u00ae<\/strong><br \/>\n<strong>corrector de volumen<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>El corrector de volumen XARTU\/1-LDVI\u2122 es el producto principal de la l\u00ednea de correctores de volumen. Esta unidad funciona con la placa de circuito probada XARTU\/1\u2122 SBC61, el coraz\u00f3n de todos los productos de la serie Eagle XA\/1. El VC-LDVI incluye un transductor de presi\u00f3n interno, un RTD (detector de temperatura de resistencia) interno, una pantalla externa y un m\u00f3dem de 2400 bps en la oferta de productos est\u00e1ndar. Un \u00edndice vertical de arrastre bajo (LDVI\u2122) opcional proporciona al usuario un respaldo mec\u00e1nico de bajo costo para el dispositivo electr\u00f3nico.<\/p>\n<p>El VC-LDVI contiene un complemento completo de los procesos est\u00e1ndar de Eagle Research, incluida la funcionalidad computacional AGA 7 y AGA 8 (Detail and Gross Method I &amp; II). Las caracter\u00edsticas adicionales incluyen una funcionalidad de comunicaci\u00f3n completa con analizadores populares para requisitos de monitoreo de energ\u00eda. El VC-LDVI es un computador de flujo completamente funcional capaz de Llamada de alarma, Control y una variedad de otras actividades relacionadas con el proceso.<\/p>\n<p>Aunque el VC-LDVI incluye un m\u00f3dem de 2400 bps como est\u00e1ndar, la unidad se puede interconectar con una amplia variedad de otros dispositivos de comunicaci\u00f3n, como m\u00f3dems de radio, celulares y satelitales. Las rotaciones del medidor en el sentido de las agujas del reloj y en el sentido contrario a las agujas del reloj se manejan mediante una simple inversi\u00f3n del \u00edndice en la carcasa.<\/p>\n<p>\u2022 \u00cdndice vertical de arrastre bajo (LDVI)<br \/>\n\u2022 Versiones unidireccionales y bidireccionales disponibles<br \/>\n\u2022 AGA 7, AGA 8 (M\u00e9todo bruto y detallado I y II) y NX-19<br \/>\n\u2022 Salidas digitales para vol\u00famenes corregidos\/no corregidos<br \/>\n\u2022 Configurable para vol\u00famenes directos, inversos y netos<br \/>\n\u2022 Configuraciones de ejecuci\u00f3n m\u00faltiple disponibles mediante una interfaz de transductor o XDI<\/p>\n<p><strong>Descargar:<\/strong><br \/>\n<a href=\"https:\/\/equipmentcontrols.com\/wp-content\/uploads\/2020\/04\/Eagle-XARTU-1.pdf\">Ficha t\u00e9cnica del corrector de volumen XARTU<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>XARTU\/1\u00ae Volume Corrector &nbsp; The XARTU\/1-LDVI\u2122 Volume Corrector is the core product in the volume corrector line. This unit runs on the proven XARTU\/1\u2122 SBC61 circuit board, heart of all products in the Eagle XA\/1 series. The VC-LDVI includes an internal pressure transducer, an internal RTD (resistance temperature detector), external display and 2400 bps modem [&hellip;]<\/p>\n","protected":false},"featured_media":822,"template":"","meta":[],"product_brand":[],"product_cat":[49,23],"product_tag":[],"class_list":{"0":"post-823","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-eagle-research-corporation","7":"product_cat-instrumentation","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.9 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>EAGLE XARTU1 Volume Corrector - ECCO<\/title>\n<meta name=\"description\" content=\"The XARTU\/1-LDVI\u2122 Volume Corrector is the core product in the volume corrector line. This unit runs on the proven XARTU\/1\u2122 SBC61 circuit board, heart of all products in the Eagle XA\/1 series. The VC-LDVI includes an internal pressure transducer, an internal RTD (resistance temperature detector), external display and 2400 bps modem in the standard product offering. An optional Low Drag Vertical Index (LDVI\u2122) provides the user with a low cost mechanical backup to the electronic device.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/equipmentcontrols.com\/es\/producto\/eagle-xartu1-volume-corrector\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EAGLE XARTU1 Volume Corrector\" \/>\n<meta property=\"og:description\" content=\"The XARTU\/1-LDVI\u2122 Volume Corrector is the core product in the volume corrector line. This unit runs on the proven XARTU\/1\u2122 SBC61 circuit board, heart of all products in the Eagle XA\/1 series. The VC-LDVI includes an internal pressure transducer, an internal RTD (resistance temperature detector), external display and 2400 bps modem in the standard product offering. An optional Low Drag Vertical Index (LDVI\u2122) provides the user with a low cost mechanical backup to the electronic device.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/equipmentcontrols.com\/es\/producto\/eagle-xartu1-volume-corrector\/\" \/>\n<meta property=\"og:site_name\" content=\"ECCO\" \/>\n<meta property=\"article:modified_time\" content=\"2020-04-30T21:54:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/equipmentcontrols.com\/wp-content\/uploads\/2020\/04\/EAGLE20XARTU120Volume20Corrector.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"860\" \/>\n\t<meta property=\"og:image:height\" content=\"860\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/\",\"url\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/\",\"name\":\"EAGLE XARTU1 Volume Corrector - ECCO\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/equipmentcontrols.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/EAGLE20XARTU120Volume20Corrector.jpg\",\"datePublished\":\"2020-04-30T16:48:35+00:00\",\"dateModified\":\"2020-04-30T21:54:04+00:00\",\"description\":\"The XARTU\\\/1-LDVI\u2122 Volume Corrector is the core product in the volume corrector line. This unit runs on the proven XARTU\\\/1\u2122 SBC61 circuit board, heart of all products in the Eagle XA\\\/1 series. The VC-LDVI includes an internal pressure transducer, an internal RTD (resistance temperature detector), external display and 2400 bps modem in the standard product offering. An optional Low Drag Vertical Index (LDVI\u2122) provides the user with a low cost mechanical backup to the electronic device.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/#primaryimage\",\"url\":\"https:\\\/\\\/equipmentcontrols.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/EAGLE20XARTU120Volume20Corrector.jpg\",\"contentUrl\":\"https:\\\/\\\/equipmentcontrols.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/EAGLE20XARTU120Volume20Corrector.jpg\",\"width\":860,\"height\":860,\"caption\":\"EAGLE20XARTU120Volume20Corrector.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/product\\\/eagle-xartu1-volume-corrector\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/equipmentcontrols.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/equipmentcontrols.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"EAGLE XARTU1 Volume Corrector\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/equipmentcontrols.com\\\/#website\",\"url\":\"https:\\\/\\\/equipmentcontrols.com\\\/\",\"name\":\"ECCO\",\"description\":\"Equipment Controls Company\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/equipmentcontrols.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"EAGLE XARTU1 Volume Corrector - ECCO","description":"El corrector de volumen XARTU\/1-LDVI\u2122 es el producto principal de la l\u00ednea de correctores de volumen. Esta unidad funciona con la placa de circuito probada XARTU\/1\u2122 SBC61, el coraz\u00f3n de todos los productos de la serie Eagle XA\/1. El VC-LDVI incluye un transductor de presi\u00f3n interno, un RTD (detector de temperatura de resistencia) interno, una pantalla externa y un m\u00f3dem de 2400 bps en la oferta de productos est\u00e1ndar. Un \u00edndice vertical de arrastre bajo (LDVI\u2122) opcional proporciona al usuario un respaldo mec\u00e1nico de bajo costo para el dispositivo electr\u00f3nico.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/equipmentcontrols.com\/es\/producto\/eagle-xartu1-volume-corrector\/","og_locale":"es_MX","og_type":"article","og_title":"EAGLE XARTU1 Volume Corrector","og_description":"The XARTU\/1-LDVI\u2122 Volume Corrector is the core product in the volume corrector line. This unit runs on the proven XARTU\/1\u2122 SBC61 circuit board, heart of all products in the Eagle XA\/1 series. The VC-LDVI includes an internal pressure transducer, an internal RTD (resistance temperature detector), external display and 2400 bps modem in the standard product offering. An optional Low Drag Vertical Index (LDVI\u2122) provides the user with a low cost mechanical backup to the electronic device.","og_url":"https:\/\/equipmentcontrols.com\/es\/producto\/eagle-xartu1-volume-corrector\/","og_site_name":"ECCO","article_modified_time":"2020-04-30T21:54:04+00:00","og_image":[{"width":860,"height":860,"url":"https:\/\/equipmentcontrols.com\/wp-content\/uploads\/2020\/04\/EAGLE20XARTU120Volume20Corrector.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/","url":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/","name":"EAGLE XARTU1 Volume Corrector - ECCO","isPartOf":{"@id":"https:\/\/equipmentcontrols.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/#primaryimage"},"image":{"@id":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/#primaryimage"},"thumbnailUrl":"https:\/\/equipmentcontrols.com\/wp-content\/uploads\/2020\/04\/EAGLE20XARTU120Volume20Corrector.jpg","datePublished":"2020-04-30T16:48:35+00:00","dateModified":"2020-04-30T21:54:04+00:00","description":"El corrector de volumen XARTU\/1-LDVI\u2122 es el producto principal de la l\u00ednea de correctores de volumen. Esta unidad funciona con la placa de circuito probada XARTU\/1\u2122 SBC61, el coraz\u00f3n de todos los productos de la serie Eagle XA\/1. El VC-LDVI incluye un transductor de presi\u00f3n interno, un RTD (detector de temperatura de resistencia) interno, una pantalla externa y un m\u00f3dem de 2400 bps en la oferta de productos est\u00e1ndar. Un \u00edndice vertical de arrastre bajo (LDVI\u2122) opcional proporciona al usuario un respaldo mec\u00e1nico de bajo costo para el dispositivo electr\u00f3nico.","breadcrumb":{"@id":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/#primaryimage","url":"https:\/\/equipmentcontrols.com\/wp-content\/uploads\/2020\/04\/EAGLE20XARTU120Volume20Corrector.jpg","contentUrl":"https:\/\/equipmentcontrols.com\/wp-content\/uploads\/2020\/04\/EAGLE20XARTU120Volume20Corrector.jpg","width":860,"height":860,"caption":"EAGLE20XARTU120Volume20Corrector.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/equipmentcontrols.com\/product\/eagle-xartu1-volume-corrector\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/equipmentcontrols.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/equipmentcontrols.com\/shop\/"},{"@type":"ListItem","position":3,"name":"EAGLE XARTU1 Volume Corrector"}]},{"@type":"WebSite","@id":"https:\/\/equipmentcontrols.com\/#website","url":"https:\/\/equipmentcontrols.com\/","name":"ECCO","description":"Empresa de Control de Equipos","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/equipmentcontrols.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"}]}},"_links":{"self":[{"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/product\/823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/media\/822"}],"wp:attachment":[{"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/media?parent=823"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/product_brand?post=823"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/product_cat?post=823"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/equipmentcontrols.com\/es\/wp-json\/wp\/v2\/product_tag?post=823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}